Trung tâm báo cháy 8 vùng UNIPOS PS4000/8

Trang Chủ >> Báo cháy-Báo trộm >> Báo cháy UNIPOS >> Trung tâm báo cháy 8 vùng UNIPOS PS4000/8
Mã số:13583910
Trung tâm báo cháy 8 vùng UNIPOS PS4000/8

Trung tâm báo cháy 8 vùng UNIPOS PS4000/8

- Fire control panel PS4000/8 is designed to operate with conventional automatic fire detectors and manual call points. The panel has outputs provided for external executive devices.

Functional 

- Identification of manual call points.

- Zone dedicated label and Zone dedicated LED indication for fire, fault, disable.

- Detection for removed fire detector.

- Automatic reset of the fault warning condition.

- Logical “AND” scenario for fire detection lines.

- EN54-2 Disabled condition and Test condition per fire detection line and fire alarm line.

- Direct mode (skip delay) function for each fire detection line.

- Test-LED functionality.

- Built-in buzzer for fire and fault condition – one tonal, continuous, can be suppressed.

- Test mode for fire alarm lines.

- Input for remote Reset fires operation.

- 8 types optional scenarios for common fire outputs and fire alarm outputs.

- Optional delay time for fire outputs activation - 1,2,3,4,5,6 or 7 minutes.

- Evacuation condition - available on access level 2.

- Optional zone dedicated relay module FD4201, each relay is common fire output corresponding to the relevant fire detection zone.

Đặc tính kỹ thuật

- Fire alarm lines:

   + Maximum number of fire detectors in a line: 32.

   + Connecting line: two-wire.

   + Maximum resistance of a line: 100Ω.

- Current thresholds for:

   + Fault condition: 0 – 6 mA.

   + Duty mode: 6 – 16 mA.

   + Fire condition: 16 – 80 mA.

   + Short circuit: > 80 mA.

- Monitored outputs for fire condition:

   + Number: 2 pcs.

   + Type: potential, relay with independent control.

   + Electrical characteristics: (19-27.5)VDC/ 1A.

- Relay outputs for fire condition:

   + Number: 2 pcs.

   + Type: potential-free,1 switching, 1 NO.

   + Electrical characteristics: 3А/125VAC, 3A/30VDC.

- Relay output for fault condition:

   + Number: 1 pcs.

   + Type: potential-free, switching.

   + Electrical characteristics: 3А/125VAC, 3A/30VDC.

- Relay output for fault condition:

   + Number: 1 pcs.

   + Type: none-monitored type activated on short-circuit (from potential free contact).

   + Electrical characteristics: 5 VDC on normal open state/ 0 VDC in activation mode.

- Performance:

   + Control over fire alarm lines and controllable outputs for fault conditions (short circuit and interruption) and automatic reset.

   + Detection of removed fire detector and automatic reset.

   + Identification of manual call points.

   + LED indication for alarm state and emergency.

   + Delay of outputs for fire condition with time period of 1, 2, 3, 4, 5, 6 or 7 minutes after fire condition is registered.

   + Option for 'LOGICAL AND' realization of two fire alarm lines.

   + Duty Mode condition with direct activation of Fire Condition 2nd Stage for two fire alarm lines.

   + Status Indication of the device for data transmission RS485.

   + Option for switching on/off interface RS485 communication.

   + Built-in sounder for fire condition – one tonal, continuous, can be switched off.

   + Built-in sounder for fault condition – one tonal, discontinuous, can be switched off.

   + Test mode for fire alarm lines.

   + Disabling fire alarm lines.

   + Disabling outputs for fire condition.

   + Expanding the options by means of extra relay outputs for fire condition for each line and built-in RS485 for operation in a local network.

   + Input for remote Reset fires operation.

- Indications of registered events:

   + Light indication: LED.

   + Sound: Built-in buzzer.

- Power supply:

   + Voltage: (100-240)VAC.

   + Frequency: 50/60 Hz.

- Backup batteries:

   + Battery type: Lead, gel electrolyte.

   + Number of batteries: 2 pcs.

   + Nominal voltage of the backup battery: 12V.

   + Nominal capacity C20: (7,0) Ah.

   + Charge voltage: 28VDC.

- Operation in Duty mode upon interruption in main power supply:

   + Lines – 24V/ 1,2Ah – 24V/ 4,5Ah – 24V/ 7,0Ah.

   + 8 lines – 16 h – 68 h – 90 h.

- Consumption on backup batteries supply:

   + Configuration of 8 lines: < 65 mA at 24VDC.

- Power supply to external devices:

   + Voltage: (19-27)VDC.

   + Maximum current value (including current of contr.outputs): 1,2A.

- Fuses:

  + Main supply 230V: 4.0A.

  + Backup battery: 6.0A.

  + Power supply to external devices: 1.85A automatic.

  + Monitored outputs: 1.1 A automatic.

- Dimension: 304mm x 222mm x 94mm.

- Weight (backup batteries not included): 0.98kg.

- Bảo hành: 12 tháng.

Giá: 5.760.000 VND